Z1: NC/PLC interface signals
19.1 Various interface signals and functions (A2)
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
1641
DB31, ...
DBX93.0 - DBX93.2 Active drive parameter set A, B, C
Edge evaluation: no
Signal(s) updated: Cyclic
Meaning
Feedback signal from the drive indicating which parameter set is active.
Active parameter set
C
B
A
1
0
0
0
2
0
0
1
3
0
1
0
4
0
1
1
5
1
0
0
6
1
0
1
7
1
1
0
8
1
1
1
Corresponding to ...
DB31, ... DBX21.0 - DBX21.2 (drive parameter set selection)
Additional
references
/IDsl/ Commissioning Manual IBN CNC: NCK, PLC, drive
DB31, ...
DBX93.3 - DBX93.4 Active motor A, B
Edge evaluation: no
Signal(s) updated: Cyclic
Meaning
Feedback signal from drive indicating which motor selection is active.
Note
When selecting the motor, to reduce the starting currents, it is possible to change between star and
delta operation.
Motor selection Meaning
B
A
Motor 1
Star operation active
0
0
Motor 2
Delta operation active
0
1
Motor 3
Reserved
1
0
Motor 4
Reserved
1
1
Corresponding to ...
DB31, ... DBX21.3 and DBX21.4 (motor selection)
DB31, ... DBX21.5 (motor being selected)
Additional
references
/IDsl/ Commissioning Manual IBN CNC: NCK, PLC, Drive
DB31, ...
DBX93.5
Drive Ready
Edge evaluation: no
Signal(s) updated: Cyclic
Signal state 1
The drive is ready.
Signal state 0
The drive is not ready.
If the signal is reset in operation, the drive is stopped (pulse inhibit or fast stop). When powering-up,
the pulses are still inhibited (cancelled) In addition, the following NC/PLC interface signals are reset:
DB10, DBX108.6 = 0 (drive ready)
DB31, ... DBX61.7 = 0 (current controller active)
DB31, ... DBX61.6 = 0 (speed controller active)