Spindle (S1)
20.9 Data lists
Turning, Milling, Nibbling
366
Function Manual, 11/2012, 6FC5397-1CP10-5BA0
Number
Identifier
Name
35130 *
GEAR_STEP_MAX_VELO_LIMIT[n]
Maximum speed of gear stage
35140 *
GEAR_STEP_MIN_VELO_LIMIT[n]
Minimum speed of gear stage
35150
SPIND_DES_VELO_TOL
Spindle speed tolerance
35160
SPIND_EXTERN_VELO_LIMIT
Spindle speed limitation via PLC
35200 *
GEAR_STEP_SPEEDCTRL_ACCEL[n]
Acceleration in speed control mode
35210 *
GEAR_STEP_POSCTRL_ACCEL[n]
Acceleration in position control mode
35300
SPIND_POSCTRL_VELO
Position control activation speed
35310
SPIND_POSIT_DELAY_TIME[n]
Positioning delay time
35350
SPIND_POSITIONING_DIR
Positioning direction of rotation for a nonsynchronized spindle
35400
SPIND_OSCILL_DES_VELO
Reciprocating speed
35410
SPIND_OSCILL_ACCEL
Oscillation acceleration
35430
SPIND_OSCILL_START_DIR
Starting direction during oscillation
35440
SPIND_OSCILL_TIME_CW
Oscillation time for M3 direction
35450
SPIND_OSCILL_TIME_CCW
Oscillation time for M4 direction
35500
SPIND_ON_SPEED_AT_IPO_START
Feed enable with spindle in setpoint range
35510
SPIND_STOPPED_AT_IPO_START
Feed enable with stationary spindle
36060
STANDSTILL_VELO_TOL
Threshold velocity "Axis/spindle stationary"
36200 *
AX_VELO_LIMIT [n]
Threshold value for velocity monitoring
36300
ENC_FREQ_LIMIT
Encoder limit frequency
36302
ENC_FREQ_LIMIT_LOW
Encoder limit frequency resynchronization
36720
DRIFT_VALUE
Drift basic value
The machine data marked with * is contained in the parameter set for a gear stage.
20.9.2
Setting data
Number
Identifier
Name
General
41200
JOG_SPIND_SET_VELO
JOG velocity for the spindle
Spindle-specific
43210
SPIND_MIN_VELO_G25
Programmable spindle speed limit G25
43220
SPIND_MAX_VELO_G26
Programmable spindle speed limit G26
43230
SPIND_MAX_VELO_LIMS
Programmable spindle speed limit G96
20.9.3
Interface signals
Number
Bit
Name
Axis-specific
VD30x 0000
-
M function for the spindle (DINT), axis-specific