Various Interface Signals (A2)
1.5 Signals from HMI to PLC
Turning, Milling, Nibbling
Function Manual, 11/2012, 6FC5397-1CP10-5BA0
29
"Command" (VB1700 1001) corresponds to the following IS:
●
"Execute command" (V1700 2001.0)
●
"Command execution error" (V1700 2001.1)
When a command > 0 is written, the job is started by the PLC. As soon as the HMI detects a
command > 0, it begins with the internal processing of this job and sets the command
(VB1700 1001) to 0.
PLC waits until the acknowledgement signal has been reached by HMI: V1700 2001.0 or
V1700 2001.1 and evaluates this immediately. The acknowledgement signals are available
for one PLC cycle once they have been received and are then automatically deleted by the
PLC operating system.
1.5
Signals from HMI to PLC
Program has been selected (V1700 2000.0)
Successful selection of the required NC program is signaled back from the HMI to the PLC.
This signal is available for one PLC cycle. It corresponds with VB1700 1000.
Program selection error (V1700 2000.1)
Failed selection of the required NC program is signaled back from the HMI to the PLC. This
signal is available for one PLC cycle. It corresponds with VB1700 1000.
Execute command (V1700 2001.0)
Successful execution of the required command is signaled back from the HMI to the PLC.
This signal is available for one PLC cycle. It corresponds with VB1700 1001.
Command execution error (V1700 2001.1)
Failed execution of the required command is signaled back from the HMI to the PLC. This
signal is available for one PLC cycle. It corresponds with VB1700 1001.