Operating Modes, Program Operation (K1)
10.3 Processing a part program
Turning, Milling, Nibbling
176
Function Manual, 11/2012, 6FC5397-1CP10-5BA0
10.3.5
Program control
Selection/activation
The user can control part program processing via the user interface. Under the "Program
control" menu (operating mode AUTOMATIC, operating area "Position") certain functions
can be selected, whereby some functions act on interface signals of the PLC. These signals
are merely selection signals from the user interface. They do not activate the selected
function.
These signal states must be transferred from the PLC user program to another area of the
data block to activate the selected functions. With program control by the PLC the signals
are to be set directly.
Table 10- 4 Program control
Function
Selection signal
Activation signal
Checkback signal
SKP skip block
V1700 0001.0
V3200 0002.0
DRY dry run feedrate
V1700 0000.6
V3200 0000.6
ROV rapid traverse
override
V1700 0001.3
V3200 0006.6
Preselection:
SBL -single block coarse
SBL -single block fine
Single block
-
-
User-specific
-
-
V3200 0000.4
M1 programmed stop
V1700 0000.5
V3200 0000.5
V3300 0000.5
PRT program test
V1700 0000.7
V3200 0001.7
V3300 0001.7
10.3.6
Program status
Program states
The status of the selected program is displayed in the interface in the AUTOMATIC and
MDA operating modes. If the JOG operating mode is selected when the program is stopped,
then the "interrupted" program status is displayed there or on reset also "aborted".
The following program states are available in SINUMERIK 802D:
●
IS "Program status aborted" (V3300 0003.4)
●
IS "Program status interrupted" (V3300 0003.3)
●
IS "Program status stopped" (V3300 0003.2)
●
IS "Program status running" (V3300 0003.0)