3 Basics
3.2 Basic parameter configuration regarding SINAMICS V90 PN
Speed Control with SINAMICS V90 and S7-1200 via PROFINET
Entry-ID: 109739222, V1.0, 07/2016
9
S
iem
e
n
s A
G
2
0
1
6
A
ll r
igh
ts
re
se
rv
e
d
3.2.2
Configure ramp-function generator via SINAMICS V-ASSISTANT
The configuration of ramp-function generator should be configured via the
SINAMICS V-ASSISTANT.
The ramp-function generator can be configured with the Parameterize menu field of
SINAMICS V-ASSISTANT.
At the tab
“
Set parameter setpoint
”, you can choose to activate the ramp-function
generator or deactivate it:
Note
There is a need to restart the drive after you
’ve activated or deactivated
the ramp-function generator.
In our example, the ramp-function generator should be activated. You can choose
to use the basic ramp-function generator or extended ramp-function generator:
Table 3-2: Ramp-function generator relevant parameters
Par. No.
Description
Set value
P1115
Ramp-function generator selection
0
P1120
Ramp-up time
10 s
P1121
Ramp-down time
10 s
P1130
Initial rounding-off time
0 s
P1131
Final rounding-off time
0 s