3. Remove the screwed connections for the phase connections
①
on the interfaces with the
diode module and with the drive cabinet on the rear of the drive.
Figure 9-27
Diode module: insulators
4. Loosen the screwed connections
①
between the diode module frame and the insulators.
Figure 9-28
Diode module: lugs
5. Lift the diode module by a few millimeters. To do so, insert the screws (size M16x150)
through the lugs
①
on the diode module frame from above.
Figure 9-29
Changing device: roller tracks