6.6
Technical data
Table 6-4
Technical data of DRIVE-CLiQ Extension
Technical data
Unit
6SL3555-0AA00-6AB0
DC link voltage
V
DC
510 … 720
Current-carrying capacity of the DC link
(T
ambient
< 40 °C)
A
DC
25
Current-carrying capacity of the electronics
A
DC
10
Mounting position/type of construction
Any
Vibration test in operation
Class 3M3 according to EN 60721-3-3
According to IEC 60068-2-6 test Fc (sinusoidal)
● 10 ... 57 Hz: 0.075 mm deflection amplitude
● 57 ... 150 Hz: 1 g acceleration amplitude
Shock test in operation
Class 3M3 according to EN 60721-3-3
According to IEC 60068-2-27 test Ea (half-sine)
● 5 g peak acceleration
● 30 ms duration
Cooling method
Natural convection
Degree of protection
IP65
Maximum length between DRIVE-CLiQ Exten‐
sion and the next axis
m
<10
DRIVE-CLiQ cable at X200 (maximum)
m
50
Weight
kg
0.8
6.6.1
Characteristics
● If the components are operated at increased ambient temperatures (40 to 55 °C) then the
DC link current must be appropriately reduced.
3H
UP
LV
VL
EO
H
RX
WS
XW
F
XU
UH
QW
$PELHQWWHPSHUDWXUH
>@
>r&@
Figure 6-3
Output current as a function of the ambient temperature
DRIVE-CLiQ Extension
6.6 Technical data
Manual, 06/2019, 6SL3097-5AW00-0BP1
115
Summary of Contents for Sinamics S120M
Page 2: ......
Page 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 185: ......