Basic functions
7.30 Web server
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
439
7.30.4.3
Access protection for parameter lists in the web server
Default rights for parameter lists
Three standard rights are specified for the parameter lists:
Standard
right
Explanation
Change list The user can create, change and delete the list.
Read
The user can read the parameters from the list.
Write
The user can write (and save) the parameters from the list.
The access rights for the parameter lists are predefined as follows:
Situation:
"SINAMICS" rights
"Administrator" rights
"SINAMICS" user creates list
Change list / Read
Change list / Read / Write
"Administrator" user creates list
Read
Change list / Read / Write
You can change the rights of individual parameter lists based on the default settings shown
in the table.
●
"SINAMICS" and "Administrator" users can reduce their own rights.
●
"Administrator" users can reduce the rights of "SINAMICS" users or expand them up to
their own level.
Note
For safety reasons, the user "administrator" should never give the user "SINAMICS" the
"write" and "change list" rights for the same parameter list at the same time.
NOTICE
Manipulation of the frequency converter parameter assignment due to password theft
If unauthorized persons obtain a user’s login data, they can manipulate the parameter
assignment and cause damage.
•
For your drive, activate the know-how protection (see Chapter "Know-how protection
(Page 976)").
•
Ensure that especially critical parameters are not included in the OEM exception list.