Basic information about the drive system
13.12 System rules, sampling times and DRIVE-CLiQ wiring
Drive functions
1026
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
The recommended settings are marked with XX in the Table; all other possible settings are
marked with X.
Table 13- 14 Pulse frequencies and current controller sampling times for servo control
Pulse fre-
quency [kHz]
Current controller sampling time [µs]
250.0
187.5
150.0
125.0
100.0
93.75
75.0
62.5
50.0
37.5
31.25
16.0
X
-
-
X
-
-
-
X
-
-
XX
13.333
-
-
X
-
-
-
X
-
-
XX
-
12.0
X
-
-
-
-
-
-
-
-
-
-
10.666
-
X
-
-
-
X
-
-
-
-
X
10.0
-
-
-
-
X
-
-
-
XX
-
-
8.888
-
-
-
-
-
-
-
-
-
X
-
8.0
X
-
-
X
-
-
-
XX
-
-
X
6.666
-
-
X
-
-
-
XX
-
X
X
-
6.4
-
-
-
-
-
-
-
-
-
-
X
5.333
-
X
-
-
-
XX
-
X
-
X
-
5.0
-
-
-
-
XX
-
-
-
X
-
-
4.444
-
-
-
-
-
-
X
-
-
-
-
4.0
X
-
-
XX
-
-
-
X
-
-
-
3.555
-
-
-
-
-
X
-
-
-
-
-
3.333
-
-
XX
-
X
-
X
-
-
-
-
3.2
-
-
-
-
-
-
-
X
-
-
-
2.666
-
XX
-
X
-
-
-
-
-
-
-
2.5
-
-
-
-
X
-
-
-
-
-
-
2.222
-
-
X
-
-
-
-
-
-
-
-
2.133
-
-
-
-
-
X
-
-
-
-
-
2.0
XX
-
-
X
X
-
-
-
-
-
-
1.777
-
X
-
-
-
-
-
-
-
-
-
1.666
-
-
X
-
-
-
-
-
-
-
-
1.6
-
-
-
X
-
-
-
-
-
-
-
1.333
-
X
X
-
-
-
-
-
-
-
-
Note
Clock cycle mix
Detailed information about the clock cycle mix for servo control is provided in Section Cycle
mix for servo control and vector control (Page 1031).