PROFIdrive
Fu
nction dia
g
ra
ms
2-
78
7
© Siemens AG 2
012 All Rights Reserved
SINAMICS
S110 List Manual (L
H7)
, 06/
2012
, 6SL3097-
4AP10-0BP3
Fi
g.
2
-3
0
244
5 – ST
W2
co
ntro
l word intercon
nection
(p2
038 =
1
)
- 2445 -
Function diagram
8
7
6
5
4
3
2
1
fp_2445_98_eng.vsd
DO: SERVO
SINAMICS S110
25.01.10 V04.04.00
PROFIdrive - STW2 control word interconnection (p2038 = 1)
<1> Used in telegrams 2, 3, 4, 102, 103.
Signal targets for STW2 in Interface Mode SIMODRIVE 611 universal (p2038 = 1)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
[3060] [3070]
-
[5040] [5210]
-
[8012]
-
-
-
[2410]
-
-
-
-
-
-
-
[2520.2]
-
-
-
-
-
-
-
p1122[0] = r2093.4
-
p1477[0] = r2093.6
p0897 = r2093.7
p1545[0] = r2093.8
-
-
p0828[0] = r2093.11
p2045 = r2050[3]
-
1 = Bypass ramp-function generator
1 = Parking axis selection
1 = Traverse to fixed endstop
Reserved
Master sign-of-life, bit 0
1 = Integrator inhibit, speed controller
Reserved
Reserved
Reserved
Reserved
Reserved
= Motor changeover, feedback signal
Master sign-of-life, bit 1
Master sign-of-life, bit 2
Master sign-of-life, bit 3
STW2.1
STW2.2
STW2.3
STW2.4
STW2.5
STW2.6
STW2.8
STW2.9
STW2.11
STW2.12
STW2.13
STW2.14
STW2.15
STW2.7
STW2.10
-
[8565]
-
p0820[0] = r2093.0
Drive data set selection DDS, bit 0
STW2.0
Inverted
[Function diagram]
signal target
[Function diagram]
internal control word
Interconnection
parameters
Meaning
Signal
<1>
<2> For a 1 signal, the integral component of the speed controller is cleared and the integrator is inhibited.
<2>
<3> Only if the function module "extended setpoint channel" is active (r0108.8 = 1).
<3>
Refer to [1020.7]
PROFIdrive sampling time