![Siemens SINAMICS S Series List Manual Download Page 1337](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_12654271337.webp)
Fa
ults an
d ala
rms
F
u
nct
ion
D
iag
ra
m
s
2
-13
37
© Siemens AG 2
007 All Rights Reserved
SINAMICS
S List Manual (LH1
), 07/200
7
Fi
gure 2-2
1
4
8
075 – F
ault/ala
rm configu
ration
- 8075 -
Function diagram
8
7
6
5
4
3
2
1
fp_8075_51_eng.vsd
DO: All objects
SINAMICS
06.03.06 V02.05.00
Faults and alarms - Fault/alarm configuration
0. Fault code
1. Fault code
19. Fault code
[0]
[1]
[19]
Changing the fault response for maximum 20 faults <1>
Fault response
Fault response
Fault response
[0]
[1]
[19]
0 = NONE
1 = OFF1
2 = OFF2
3 = OFF3
0. Fault code
1. Fault code
19. Fault code
[0]
[1]
[19]
Changing the acknowledge mode for maximum 20 faults <1>
Acknowledge mode
Acknowledge mode
Acknowledge mode
[0]
[1]
[19]
1 = Acknowledgment is only possible using POWER ON
2 = Acknowledgment IMMEDIATELY after the cause has been removed.
<1> The fault response, acknowledge mode and message type for all faults and alarms are set to meaningful default values in the factory setting.
Changes that may be required are only possible in specific value ranges specified by SIEMENS.
When the message type is changed, the supplementary information is tranferred from fault value r0949 to alarm value r2124 and vice versa.
0. Fault/alarm code
1. Fault/alarm code
19. Fault/alarm code
[0]
[1]
[19]
Changing the message type - fault <==> alarm for maximum 20 faults/alarms <1>
Fault/alarm type
Fault/alarm type
Fault/alarm type
[0]
[1]
[19]
1 = Fault
2 = Alarm
p2100
p2101
p2118
p2119
p2126
p2127
4 = STOP1
5 = STOP2
6 = DCBRK
Background
Refer to [1020.7]
3 = Acknowledge only when the PULSES ARE INHIBITED.
7 = Encoder
3 = No message