![Siemens SINAMICS S Series List Manual Download Page 1172](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_12654271172.webp)
F
u
nct
ion
D
iag
ra
m
s
PR
OFIdriv
e
2-
11
72
© Siemens AG
2007 All Rights Reserved
S
IN
A
MICS
S List Manua
l (
L
H1), 0
7
/2007
Fi
gure 2-6
4
2
460 – IF1 recei
v
e te
legram, free
in
te
rconne
cti
on via BIC
O
(p092
2 = 999
)
- 2460 -
Function diagram
8
7
6
5
4
3
2
1
fp_2460_01_eng.vsd
DO: SERVO, VECTOR
SINAMICS S
28.06.07 V02.05.01
PROFIdrive - IF1 receive telegram, free interconnection via BICO (p0922 = 999)
PZD receive word 1
PZD receive word 2
r2060[0]
DWORD
r2060[4]
DWORD
r2091.0
r2050[1]
r2091.15
r2090.0
r2050[0]
r2090.15
...
PZD receive word 3
PZD receive word 4
r2060[2]
DWORD
r2093.0
r2050[3]
r2093.15
r2092.0
r2050[2]
r2092.15
...
...
r2060[1]
DWORD
...
r2050[4]
r2060[3]
DWORD
PZD receive word 32
r2050[30]
r2060[30]
DWORD
r2050[31]
(0)
p2099[0]
r2095.0
r2095.15
(0)
p2099[1]
Reference quantities for further interconnection
p200x
<3>
<3>
2 connector-binector converter
<2>
r2094.0
r2094.15
<1> In order to maintain the PROFIdrive profile, receive word 1 must be used as control word (STW1) (due to bit 10 "control requested").
<2> Using the connector-binector converters, the bits can be extracted from two of the PZD receive words 5 to 32 and used as binectors.
<3> The following representation applies for words: 4000 hex = 100 % for double words 4000 0000 hex = 100 %.
The reference variables p200x apply for the ongoing interconnection (100 % -> p200x).
The following applies for temperature values: 100° C -> 100 % = 4000 hex or 4000 0000 hex; 0° C -> 0 %.
<4> The number of PZD receive words depends on the drive object type.
<5> The connector-binector converter only converts the lower 16 bits irrespective of the input variable.
p2098[1].0
p2098[1].15
p2098[0].15
p2098[0].0
<1>
PROFIdrive
receive telegram
1
0
1
1
0
1
1
0
1
1
0
1
<2>
Drive object n
Header
Drive object 1
Drive object 2
.
.
.
.
.
.
Drive object m
Trailer
p2048
PZD receive word 5
PZD receive word 31
r2050[29]
r2060[29]
DWORD
PZD receive word 30
PZD receive word 29
r2050[28]
r2060[28]
DWORD
r2060[5]
DWORD
r2050[5]
PZD receive word 6
Refer to [1020.7]
PROFIdrive sampling time
PROFIBUS
PROFINET
<4>