Internal Analog Input Menus
Table 6-25
Internal Analog Input 1 Menu (2815) Parameters
Parameter
ID
Unit
Default
Min
Max
Description
Type
2816
1
Set the operational mode for internal AI1:
• 0 to 20 mA
• 4 to 20 mA
Hardware Zero
2817
0
-200
200
Internal analog input 1 zero
Hardware Span
2818
1
0.75
1.25
Internal analog input 1 span
Table 6-26
Internal Analog Input 2 Menu (2825) Parameters
Parameter
ID
Unit
Default
Min
Max
Description
Type
2826
1
Set the operational mode for internal AI2:
• 0 to 20 mA
• 4 to 20 mA
• 0 to 10 V
• RTD
Hardware Zero
2827
0
-200
200
Internal analog input 2 zero
Hardware Span
2828
1
0.75
1.25
Internal analog input 2 span
RTD Alpha Value
2101
0.39
0.1
0.7
Set the internal I/O RTD's analog input alpha
value.
Table 6-27
Internal Analog Input 3 Menu (2835) Parameters
Parameter
ID
Unit
Default
Min
Max
Description
Type
2836
1
Set the operational mode for internal AI3:
• 0 to 20 mA
• 4 to 20 mA
• 0 to 10 V
• RTD
Hardware Zero
2837
0
-200
200
Internal analog input 3 zero
Hardware Span
2838
1
0.75
1.25
Internal analog input 3 span
RTD Alpha Value
2102
0.39
0.1
0.7
Set the internal I/O RTD's analog input alpha
value.
Parameter Assignment/Addressing
6.6 Options for Drive Menu (2) - second part
Control Manual
116
Operating Manual, A5E50491925A
Summary of Contents for SINAMICS PERFECT HARMONY GH180
Page 2: ......
Page 22: ...Table of contents NXGPro Control Manual 20 Operating Manual A5E50491925A ...
Page 24: ...Security NXGPro Control Manual 22 Operating Manual A5E50491925A ...
Page 504: ...NEMA Table NXGPro Control Manual 502 Operating Manual A5E50491925A ...
Page 517: ...Index D NXGPro Control Manual Operating Manual A5E50491925A 515 ...
Page 518: ...Index NXGPro Control Manual 516 Operating Manual A5E50491925A ...
Page 530: ...Glossary NXGPro Control Manual 528 Operating Manual A5E50491925A ...
Page 537: ......