B.2.4.3
Actual value channels
Table B-17
Power Stack Adapter 2: Actual value channels
Single fiber-optic cable
Meaning, actual value acquisition
Technical specifications
X70, X71
DC-link voltages
Fiber-optic cable type: 2 mm
plastic optical fiber (POF)
Max. length of fiber-optic cable:
20 m
X72, X73
Output currents
X74, X75
Output voltages
X76 to X78
N.C.
X79
Voltage sensing braking chopper
B.2.4.4
Trip line
Table B-18
Power Stack Adapter 2: Trip line
Fiber-optic cable
Meaning
Technical data
X81
● Two PSAs Duplex fiber-
optic cable;
● > two PSAs Single fiber-
optic cable)
Trip line for direct data ex‐
change between PSAs
Fiber-optic cable type:
2 mm plastic optical fiber (POF)
Max. length of fiber-optic cable: 10 m
B.2.4.5
DRIVE-CLiQ interface
Table B-19
DRIVE-CLiQ interface
Pin
Signal name
Technical data
1
TXP
Transmit data +
2
TXN
Transmit data -
3
RXP
Receive data +
4
Reserved, do not use
5
Reserved, do not use
6
RXN
Receive data -
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
Power supply
B
M (0 V)
Electronics ground
Blanking plate for DRIVE-CLiQ interface: Molex, order number: 85999-3255.
The maximum DRIVE-CLiQ cable length is 50 m.
Technical data and drawings
B.2 Terminal assignments
SINAMICS GM150 6SL3815-2LN41-4AA2
242
Operating Instructions 04/2017
Summary of Contents for SINAMICS GM150
Page 2: ...20 04 2017 13 25 V27 00 ...
Page 16: ...Table of contents SINAMICS GM150 6SL3815 2LN41 4AA2 16 Operating Instructions 04 2017 ...
Page 228: ...Spare parts SINAMICS GM150 6SL3815 2LN41 4AA2 228 Operating Instructions 04 2017 ...
Page 232: ...Service Support SINAMICS GM150 6SL3815 2LN41 4AA2 232 Operating Instructions 04 2017 ...
Page 256: ...Index SINAMICS GM150 6SL3815 2LN41 4AA2 256 Operating Instructions 04 2017 ...
Page 257: ......