![Siemens Sinamics GM150 6SL3835-2LN44-2AA0 Operating And Installation Instructions Download Page 115](http://html.mh-extra.com/html/siemens/sinamics-gm150-6sl3835-2ln44-2aa0/sinamics-gm150-6sl3835-2ln44-2aa0_operating-and-installation-instructions_378208115.webp)
7. You have two parameter selection options:
– All parameters of the selected DO
Press the <▼> function key to select "All parameters". Then confirm the selection with
OK. A list of all parameters of the selected DO is displayed.
– Selection of plausible parameters (see "List of the signals for the operation screen"
below) of the selected DO.
Select a parameter from the list of the signals for the operation screen of the selected DO.
The selected parameters from this list are displayed in the operation screen with an
abbreviated name (e.g. NSOLL).
8. Select the desired parameter or enter the parameter from the numeric keypad.
9. Confirm the setting by pressing the <OK> function key. The "Please wait" message appears
briefly. Then the operation screen appears in the configuration you set.
9(&725$86
3%62//
,B,67
$HII
$867
)B$86
+]
3:,5. N:
/7,7
+HOS
&KDQJH
6HO3DU
'LDJ
List of signals for the operation screen
Table 8-1
List of signals for the operation screen
Signal
Parameter
Short name
Unit
Scaling
(100% = ...)
DO: Vector MV
Factory setting (entry no.)
Speed setpoint upstream of RFG (1)
r1114
NSETP
1/min
p2000
Output frequency (2)
r0024
F_OUT
Hz
Reference frequen‐
cy
Output smoothed (3)
r0032
P_ACT
kW
r2004
DC-link voltage smoothed (4)
r0026
UDC
V
p2001
Actual speed smoothed (5)
r0021
N_ACT
1/min
p2000
Actual absolute current smoothed (6)
r0027
I_IST
A
p2002
Motor temperature (7)
r0035
T_MOT
°C
Reference tempera‐
ture
Motor temperature (8)
r0037
T_LT
°C
Reference tempera‐
ture
Actual torque smoothed (9)
r0031
M_ACT
Nm
p2003
Drive output voltage smoothed (10)
r0025
C_OUT
V
p2001
Speed setpoint smoothed
r0020
NSETP
1/min
p2000
Control factor smoothed
r0028
%
Reference control
factor
Field-producing current component
r0029
A
p2002
Torque-producing current component
r0030
A
p2002
Operation
8.3 Operation via the AOP30 operator panel
SINAMICS GM150 6SL3835-2LN44-2AA0
Operating Instructions Rev.201910281250 MUSTER
115
Summary of Contents for Sinamics GM150 6SL3835-2LN44-2AA0
Page 2: ...28 10 2019 12 50 V32 00 ...
Page 232: ...Index SINAMICS GM150 6SL3835 2LN44 2AA0 232 Operating Instructions Rev 201910281250 MUSTER ...
Page 233: ......
Page 236: ......
Page 238: ......