S
IN
A
MICS
G1
30/G150
List
Manual (LH
2)
, 07/2
016
, A5E0326347
9A
12
89
3
F
un
ction dia
g
ra
ms
3.19
Sig
nals an
d mon
ito
rin
g
fu
nctions
F
ig.
3
-169
80
13 – Loa
d
mo
nitoring
(r01
08.17
=
1
)
- 8013 -
Function diagram
8
7
6
5
4
3
2
1
fp_8013_54_eng.vsd
DO: SERVO, VECTOR
S120/S150/G130/G150
11.04.12 V04.08.00
Signals and monitoring functions - Load monitoring (r0108.17 = 1)
<1> The response to these faults can be defined.
<2> Only for VECTOR.
<3> Only for SERVO.
[8010.2]
M [Nm]
0
T
Load monit t_del
0.00...65.00 [s]
p2192[D] (10.00)
p0115[6] (4000.00 μs)
0
1
p2149.1
A07920 ... A07922
r2198.11
F07923 ... F07925
r2198.12
[2536.3]
Load monitoring response
p2181[D](0)
Evaluation
A07920
"Torque/speed too low"
A07921
"Torque/speed too high"
A07922
"Torque/speed outside tolerance"
F07923
"Torque/speed too low"
F07924
"Torque/speed too high"
F07925
"Torque/speed outside tolerance"
<1>
(0)
(1)
Load monitoring disabled
(2)
(3)
(4)
(5)
(6)
<1>
<1>
[2536.3]
A07926
"Envelop characteristic, parameter not value"
r0080
M_act
r2169
n_act smooth signal
0
1
p2149.1
M_thresh 3 upper
0.00...20 000 000.00 [Nm]
p2189[D] (10 000 000.00)
M_thresh 3 lower
0.00...20 000 000.00 [Nm]
p2190[D] (0.00)
M_thresh 2 upper
0.00...20 000 000.00 [Nm]
p2187[D] (10 000 000.00)
M_thresh 2 lower
0.00...20 000 000.00 [Nm]
p2188[D] (0.00)
M_thresh 1 upper
0.00...20 000 000.00 [Nm]
p2185[D] (10 000 000.00)
M_thresh 1 lower
0.00...20 000 000.00 [Nm]
p2186[D] (0.00)
n_threshold 1
0.00...210 000.00 [rpm]
p2182[D] (150.00)
n_threshold 2
0.00...210 000.00 [rpm]
p2183[D] (900.00)
n_threshold 3
0.00...210 000.00 [rpm]
p2184[D] (1500.00)
Tolerance
bandwidth
n [rpm]
[5730.1] <3>
[6714.8] <2>
F07928
"Internal voltage protection initiated"
<2>
M_act_filt T
0...1000000 [ms]
p3233[D] (0)
Summary of Contents for SINAMICS G130
Page 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Page 2: ......
Page 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Page 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Page 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...