r3927[0...n]
Motor data identification control word / MotID STW
Access level: 3
Calculated: CALC_MOD_ALL Data type: Unsigned32
Can be changed: -
Scaling: -
Dynamic index: DDS, p0180
Unit group: -
Unit selection: -
Function diagram: -
Min:
-
Max:
-
Factory setting:
-
Description:
Successfully completed component of the last motor data identification carried out.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Stator inductance estimate no measurement
Yes
No
-
02
Rotor time constant estimate no measurement
Yes
No
-
03
Leakage inductance estimate no measurement
Yes
No
-
05
Determine Tr and Lsig evaluation in the time range
Yes
No
-
06
Activate vibration damping
Yes
No
-
07
Deactivate vibration detection
Yes
No
-
11
Deactivate pulse measurement Lq Ld
Yes
No
-
12
Deactivate rotor resistance Rr measurement
Yes
No
-
14
Deactivate valve interlocking time measurement
Yes
No
-
15
Determine only stator resistance, valve voltage fault, dead
time
Yes
No
-
16
Short motor identification (lower quality)
Yes
No
-
17
Measurement without control parameter calculation
Yes
No
-
18
After motID direct transition into operation
Yes
No
-
19
After MotID automatically save results
Yes
No
-
20
Estimate cable resistance
Yes
No
-
21
Calibrating the output voltage measurement
Yes
No
-
22
Only identify circle
Yes
No
-
23
Deactivate circle identification
Yes
No
-
24
Circle identification with 0 and 90 degrees
Yes
No
-
Dependency:
See also: r3925
Note
The parameter is a copy of p1909.
r3928[0...n]
Rotating measurement configuration / Rot meas config
Access level: 3
Calculated: CALC_MOD_ALL Data type: Unsigned16
Can be changed: -
Scaling: -
Dynamic index: DDS, p0180
Unit group: -
Unit selection: -
Function diagram: -
Min:
-
Max:
-
Factory setting:
-
Description:
Successfully completed component of the last rotating measurement carried out.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
01
Saturation characteristic identification
Yes
No
-
02
Moment of inertia identification
Yes
No
-
03
Re-calculates the speed controller parameters
Yes
No
-
04
Speed controller optimization (vibration test)
Yes
No
-
05
q leakage inductance ident. (for current controller adaptation) Yes
No
-
11
Do not change the controller parameters during the
measurement
Yes
No
-
12
Measurement shortened
Yes
No
-
13
After measurement direct transition into operation
Yes
No
-
Parameters
7.3 Parameters
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
657