Operation
6.8 Communication via RS485
Inverter cabinet units
Operating Instructions, 12/2014, A5E32923362A
227
6.8.2.5
USS process data channel (PZD)
Description
The process data channel (PZD) contains the following data depending on the transmission
direction:
●
Control words and setpoints for the slave
●
Status words and actual values for the master
Figure 6-18 Process data channel
The first two words are:
●
Control 1 (STW1) and main setpoint (HSW)
●
Status word 1 (ZSW1) and main actual value (HIW)
If p2022 is greater than or equal to 4, then the inverter receives the additional control word
(STW2).
You define the sources of the PZD using parameter p2051.
For further information, please refer to the List Manual.
6.8.2.6
Time-out and other errors
You require the telegram runtimes in order to set the telegram monitoring. The character
runtime is the basis of the telegram runtime:
Table 6- 18 Character runtime
Baud rate in bit/s
Transmission time per bit
Character run time (= 11 bits)
9600
104.170 µs
1.146 ms
19200
52.084 µs
0.573 ms
38400
26.042 µs
0.286 ms
115200
5.340 µs
0.059 ms
Summary of Contents for SINAMICS G120P
Page 1: ......
Page 2: ......
Page 8: ...Preface Inverter cabinet units 8 Operating Instructions 12 2014 A5E32923362A ...
Page 16: ...Table of contents Inverter cabinet units 16 Operating Instructions 12 2014 A5E32923362A ...
Page 432: ...Application examples Inverter cabinet units 432 Operating Instructions 12 2014 A5E32923362A ...
Page 496: ......