Commissioning
5.5 Restoring the factory setting
Converter with control units CU250D-2
Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
83
5.5.2
Resetting the safety functions to the factory setting
Procedure with STARTER
To reset the safety function settings to the factory setting without changing the standard
settings, proceed as follows:
1.
Go online.
2.
Open the screen form of the safety functions.
3.
Select the button to restore the factory settings.
4.
Enter the password,for the safety functions.
5.
Confirm that the parameters have been saved (RAM to ROM).
6.
Go offline.
7.
Switch off the inverter supply voltage.
8.
Wait until all LEDs on the inverter go dark.
9.
Switch on the inverter supply voltage again.
You have restored the safety functions in the inverter to the factory settings.