Commissioning
5.4 Basic commissioning with a PC
Converter with control units CU250D-2
Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
69
5.4
Basic commissioning with a PC
PC-based commissioning tools
STARTER and Startdrive are PC tools to commission Siemens inverters. The graphic user
interface supports you when commissioning your inverter. Most of the inverter functions are
available in screen forms.
The screen forms that are shown in this manual show generally valid examples. The number
of setting options available in screen forms depends on the particular inverter type.
Preconditions for commissioning
You can access the inverter with STARTER or Startdrive either
via a USB connection or via the fieldbus.
System requirements and download:
•
STARTER download
http://support.automation.siemens.com/WW/view/en/10804
•
Startdrive
http://support.automation.siemens.com/WW/view/en/88851
Help for operation and for the functions of the commissioning tools:
●
STARTER videos (
http://www.automation.siemens.com/mcms/mc-drives/en/low-voltage-
inverter/sinamics-g120/videos/Pages/videos.aspx
●
Startdrive tutorial (
http://support.automation.siemens.com/WW/view/en/73598459
Overview of basic commissioning
Basic commissioning using a PC essentially consists of the following steps:
1.
Creating a project
2.
Integrate an inverter into the project
3.
Go online and start basic commissioning
4.
Carry out basic commissioning
5.
Identify motor data
Steps 1-5 are described below.