Advanced commissioning
7.6 Basic positioner and position control
Converter with control units CU250D-2
184
Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
7.6.6.3
Cam sequencer
Description
The converter compares the position actual value with two different positions and therefore
simulates two independent cam switching signals.
If you need this function, set the cam switching position to match your particular application
and appropriately interconnect the cam switching signal.
Parameter
Meaning
p2547
Cam switching position 1
p2548
Cam switching position 2
r2683.8
Position actual value <= cam switching position 1
r2683.9
Position actual value <= cam switching position 2