3
F
unction
d
iag
ram
s
3.16
Te
chno
log
y function
s
SINAMICS
G120D
74
8
L
ist Manual (LH
14)
, 01/2
016
, A5E3384231
3
F
ig.
3
-136
70
10 – Friction
ch
aracteristic
- 7010 -
Function diagram
8
7
6
5
4
3
2
1
fp_7010_97_53.vsd
Technology functions
SINAMICS G120D
09.12.2015
V4.7.6
Friction characteristic
0
0
1
Sign
+ or -
<1>
M [Nm]
Frict rec act
0 ... 3
p3845 (0)
r0063
n_act [rpm]
r0063
n_act [rpm]
[0]
Frict rec t_RU/RD
0.000 ... 999999.000 [s]
p3846 [D] (10.000)
r3841
Frict outp [Nm]
Friction M0
p3830 [D]
Friction M9
p3839 [D]
r1539
M_max lower eff [Nm]
Frict act
p3842
Friction n9
p3829 [D]
Friction n0
p3820 [D]
Drive ON from the sequence control
Friction characteristic record active (p3845 > 0)
Start ramp-function generator
Record friction characteristic
Play friction characteristic
Friction characteristic positive direction
r3840.8
Friction characteristic record aborted
r3840.3
Friction characteristic record completed
r3840.2
Friction characteristic record activated
r3840.1
A07961
"Friction characteristic record activated"
F07963
"Friction characteristic record
interrupted"
Friction ZSW
r3840
r3840
Frict rec t_warm
0.000 ... 3600.000 [s]
p3847 [D] (0.000)
A07960
"Friction characteristic incorrect"
Friction characteristic OK
r3840.0
n [rpm]
p3845
= 0: Friction characteristic record deactivated
= 1: Friction char record activated for all directions
= 2: Friction char record activated for positive direction
= 3: Friction char record activated for negative direction
<1>
[6640.8]
[6640.8]
[3080.7]
r1538
M_max upper eff [Nm]
[6710.1]