3
F
unction
d
iag
ram
s
3.5
C
ommu
nication
PROFId
rive
(P
ROFIBUS/PROFINET
),
EtherNet/I
P
SINAMICS
G120D
62
6
L
ist Manual (LH
14)
, 01/2
016
, A5E3384231
3
F
ig.
3
-25
24
60 – PROF
Id
rive -
MELDW
status word in
terco
nnection
- 2460 -
Function diagram
8
7
6
5
4
3
2
1
fp_2460_97_04.vsd
PROFIdrive (PROFIBUS/PROFINET), EtherNet/IP
G120D CU250D-2
09.12.2015
V4.7.6
PROFIdrive - MELDW status word interconnection
MELDW.0
MELDW.1
MELDW.2
MELDW.3
MELDW.4
MELDW.5
MELDW.6
MELDW.8
MELDW.9
MELDW.11
MELDW.12
MELDW.13
MELDW.14
MELDW.15
MELDW.7
MELDW.10
-
p2082[6] = r2135.14
p2082[7] = r2135.15
p2082[8] = r2199.4
-
-
p2082[11] = r0899.8
p2082[0] = r2199.5
p2082[1] = r2199.11
[2537.7]
[2537.7]
-
-
[2548.7]
[2548.7]
[2537.7]
-
-
[2503.7]
[2537.7]
[2537.7]
[8010]
[8010]
-
-
[8016]
[8021]
[8011]
-
-
[2610]
[8011]
[8012]
-
-
-
-
-
-
-
-
-
-
Signal sources for MELDW
Signal
Meaning
Interconnection
parameters
[Function diagram]
internal control word
[Function diagram]
signal target
Inverted
1 = Ramp-up/ramp-down completed
1 = No motor overtemperature alarm
1 = No alarm, thermal overload, power unit
1 = Speed setpoint - actual value deviation within tolerance t_on
Reserved
1 = Torque utilization < torque threshold value 2 (p2194)
-
p2082[3] = r2197.1
p2082[2] = r2199.0
Reserved
1 = Controller enable
1 = Drive ready
1 = Pulses enabled
Reserved
p2082[12] = r0899.7
p2082[13] = r0899.11
-
-
[2503.7]
[2503.7]
-
-
[2610]
[2610]
-
-
-
-
-
-
1 = |n_act| < speed threshold value 3 (p2161)
1 = |n_act| > speed threshold value 2 (p2155)
Reserved
Reserved
Reserved
<1>
<1>
Used in telegrams 110, 111.