A.6.2
Machine documentation
Machine or plant description
Designation
Type
Serial number
Manufacturer
End customer
Overview diagram of the machine and/or system:
Inverter data
The inverter data include the hardware version of the safety-relevant inverter.
Labeling the drive
Article number and hardware version of the inverter
Function table
The active safety functions depending on the operating mode and safety equipment are shown
in the function table.
Operating
mode
Safety equipment
Drive
Selected safety function
Checked
Table A-8
Example of a function table
Operating
mode
Safety equipment
Drive
Selected safety function
Checked
Automatic
Protective door closed
Conveyor belt
---
---
Protective door open
Conveyor belt STO
Emergency Stop button
pressed
Conveyor belt STO
Appendix
A.6 Acceptance test for the safety function
SINAMICS G120C converter
456
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34263257B AF