![Siemens SINAMICS G120C Operating Instructions Manual Download Page 422](http://html.mh-extra.com/html/siemens/sinamics-g120c/sinamics-g120c_operating-instructions-manual_376473422.webp)
10.10
Accessories
10.10.1
Line reactor
The assignment of a suitable line reactor to the inverter is provided in the following Chapter:
Dimensions and mounting dimensions:
Mounting base components (Page 47)
Mounting the line reactor (Page 57)
Table 10-15 Technical data of the line reactors
Article no.
6SE6400-3CC00-2AD3
6SE6400-3CC00-4AD3
6SE6400-3CC00-6AD3
Inductance
2.5 mH
2.5 mH
2.5 mH
Power loss
25 W
25 W
40 W
Degree of protection
IP20
IP20
IP20
Weight
1.3 kg
1.4 kg
1.4 kg
Table 10-16 Technical data of the line reactors
Article no.
6SL3203-0CE13-2AA0
6SL3203-0CE21-0AA0
6SL3203-0CE21-8AA0
Inductance
2.5 mH
2.5 mH
0.5 mH
Power loss
25 W
40 W
55 W
Degree of protection
IP20
IP20
IP20
Weight
1.1 kg
2.1 kg
3.0 kg
Table 10-17 Technical data of the line reactors
Article no.
6SL3203-0CE23-8AA0
Inductance
0.3 mH
Power loss
90 W
Degree of protection
IP20
Weight
7.8 kg
Technical data
10.10 Accessories
SINAMICS G120C converter
422
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34263257B AF