Functions
7.9 Technological functions
Inverter with CU240B-2 and CU240E-2 Control Units
204
Operating Instructions, 07/2010, FW 4.3.2, A5E02299792B AA
Table 7- 34 Advanced settings
Parameter Description
P1201
Flying restart enable signal source (factory setting: 1)
Defines a control command, e.g. a digital input, through which the flying restart function
is enabled.
P1202
Flying restart search current (factory setting 100 %)
Defines the search current with respect to the motor magnetizing current (r0331), which
flows in the motor while the flying restart function is being used.
P1203
Flying restart search speed factor (factory setting 100 %)
The value influences the speed with which the output frequency is changed during the
flying restart. A higher value results in a longer search time.