Connect cables at the inverter so that they are EMC compliant
Attach the cable tie holders to the Power Mod‐
ule as shown to the left in the diagram before
you establish the connections.
Fix the line connecting cable using a cable tie
as shown in
①
.
Fix the shield of the motor connecting cable
using a hose clamp (
②
).
Connect the shield of the control cable with the
shield plate of the Control Unit (
③
) using a
steel band. Also attach the control cable to the
Power Module using a cable tie (
④
).
Connecting-up
5.2 Connecting the line and motor cable at the inverter
Power Module PM240-2