11.2
Performance ratings Power Module - PM240M
General performance ratings
Feature
Specification
Line operating voltage &
power ranges
3 AC 380 V (- 10%) … 480 V (+ 10%)
High Overload: 0.37 kW … 4.0 kW (0.5 hp … 5.0 hp)
Input frequency
47 Hz … 63 Hz
Output frequency
0 Hz … 650 Hz
cos φ
0.95
Converter efficiency
95% … 97%
Overload capability (HO) 2 x Nominal output current for 3 seconds followed by 1.5 x Nominal output
current for 57 seconds every 300 seconds (averages as 110%).
For 4 kW variant:
1.6 x Nominal output current for 3 seconds followed by 1.5 x Nominal output
current for 57 seconds every 300 seconds (averages as 110%).
Inrush current
Less than rated input current
Pulse frequency
4 kHz (standard); 4 kHz … 16 kHz (in 2 kHz steps)
Electromagnetic compati‐
bility
Internal Class A filters according to EN 55011
Protection level
IP65/IP66 (when Power Module and Control Unit is fully assembled).
Temperature range
CU: -10 °C … +55 °C (14 °F … 131 °F) - High Overload (HO)
Storage temperature
-40 °C … +70 °C (-40 °F … 158 °F)
Humidity
< 95% RH - non-condensing
Operational altitude
Up to 1000 m (3280 ft) above sea level without derating
Protection features
Undervoltage, Overvoltage, Overload, Ground faults, Short circuit, Stall pre‐
vention, Motor blocking protection, Motor overtemperature, Power Module
overtemperature, Parameter interlock
Standards
UL, cUL, CE, C-tick
CE mark
Conformity with EC Low Voltage Directive 73/23/EEC and filtered versions
also Electromagnetic Compatibility Directive 89/336/EEC
EM Brake
180 V DC (400 V half-wave rectified) 1A maximum
Technical data
11.2 Performance ratings Power Module - PM240M
Distributed converter for SIMOGEAR geared motors
390
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL