5.6
Series commissioning
Overview
Series commissioning is the commissioning of several identical converters. During series
commissioning, it is sufficient to commission one of the converters and then transfer the
settings of the first converter to additional converters.
Precondition
The following preconditions apply to the converters regarding series commissioning:
• All converters have the same article number
• The converters to which the settings are transferred have the same or a higher firmware
version as the source converter with the original settings.
Function description
Procedure
1. Commission the first converter.
2. Back up the settings of the first converter to an external storage medium.
Uploading the converter settings (Page 137)
3. Transfer the settings from the first converter to another converter via the data storage
medium.
Downloading the converter settings (Page 367)
Commissioning
5.6 Series commissioning
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
135