Function diagrams
Vector control
2-458
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Picture 2-75 6491 – Flux control configuration
- 6491 -
Function diagram
8
7
6
5
4
3
2
1
fp_S01_6491_en.vsd
DO: VECTOR
SINAMICS G
17.12.04
V02.02.00
Vector open-loop - closed-loop control status words - flux control configuration
1
2
1 = Flux setpoint, soft starting active
Meaning
1 = Flux setpoint, differentiation active
1 = Flux build-up control active
0
Bit No.
Flux control, configuration
[6723.6]
[6722.3]
p1401[D]
p1401[D]
F_ctrl config
[6723.7]
1
1
0
Factory setti
n
g
Refer to [1020.7]
p0115[y] (MM)
3
Reserved
4
Reserved
Reserved
5
6
7
Reserved
3
Reserved
8
Reserved
9
10
Reserved
11
Reserved
12
Reserved
Reserved
13
Reserved
14
Reserved
15
Reserved