![Siemens SINAMICS G List Manual Download Page 451](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180451.webp)
Vector control
Function diagrams
2-451
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Picture 2-68 6060 – Torque setpoint
- 6060 -
Function diagram
8
7
6
5
4
3
2
1
fp_S01_6060_en.vsd
DO: VECTOR
SINAMICS G
17.12.04
V02.02.00
Vector speed control with encoder - torque setpoint
M_max upper sc
a
l
(100)
p1540[C]
r1539
M_max lower effective
≥
1
M_set
(0)
p1503[C]
M_max lower scal
(100)
p1541[C]
r1538
M_max upper effective
1 = M_ctrl active
r1406.12
p1300 = MCtrl
0
1
M_set from the speed controller
[6040]
1 = M_ctrl active
r1407.2
0
[6492.7]
Calculated acceleration torque
[6031.8]
M_suppl 1
(0)
p1511[C]
0
1
0
1
0
M_suppl total
r1515
[6640.8]
Torque limiting, upper activ
e
r1407.8
Torque limiting lower active
r1407.9
[6030.1]
[6710.1]
[2522.3]
1 = Speed controller limited
r1407.7
Torque limiting, upper activ
e
r1407.8
Torque limiting
r0079
M_set total
[2522.3]
1 = M_max output n_ctrl lower lim
it
r1547[1]
1 = M_max output n_ctrl upper limit
r1547[0]
r1508
M_set before M_suppl
r1518
Accel_torque
[6030.5]
1 = Magnetization completed
r1405.4
[6640.8]
Refer to [1020.7]
p0115[y] (MM)
Torque limiting lower active
r1407.9
[2522.3]
[2522.3]
[2522.3]
+
+
+
+
[2520.7]
p1501
M_suppl 2 scal
-10 000%...10 00
0
%
p1514[D] (100.0%)
M_suppl 1 scal
(0)
p1512[C]
M_suppl 2
(0)
p1513[C]
+
+
[6030.1]
[6722.1]
0
1
0
≥
1
p1400.14
[2501.7]
p0856
r0898.12
1
0
0