Appendix
A.1 New and extended functions
Converter with the control units CU240D-2
Operating Instructions, 04/2018, FW V4.9 SP10, A5E34262100B AF
323
A.1.2
Firmware version 4.7 SP9
Table A- 2
New functions and function changes in firmware 4.7 SP9
Function
SINAMICS
G120
G120D
1
Support of PM240-2 FSG Power Modules
-
-
✓
✓
✓
✓
-
-
-
2
Support of PM240-2 Power Modules in push-through technology, frame
sizes FSD … FSF, for the following voltages:
•
3 AC 200 V … 240 V
•
3 AC 380 V … 480 V
•
3 AC 500 V … 690 V
-
-
✓
✓
✓
✓
-
-
-
3
Shortened switch-on time for PM330 Power Modules
-
-
✓
-
-
-
-
-
-
4
Expansion of the support for 1FP1 synchronous-reluctance motor with the
following inverters:
•
SINAMICS G110M
•
SINAMICS G120D
•
SINAMICS G120 with CU240B-2 or CU240E-2 Control Unit
A PM240-2 Power Module is required to operate a 1FP1 synchronous-
reluctance motor with SINAMICS G120
✓
-
✓
✓
✓
-
✓
-
-
5
Support of 1FP3 synchronous-reluctance motors
A PM240-2 Power Module is required to operate a 1FP3 synchronous-
reluctance motor along with a selective release from SIEMENS
-
-
✓
-
-
-
-
-
-
6
Support of 1LE5 induction motors
-
✓
✓
✓
✓
✓
-
-
-
7
The inverter supports forming of the PM330 Power Module DC link ca-
pacitors
-
-
✓
-
-
-
-
-
-
8
Setting option for two output reactors using parameter p0235 at the
SINAMICS G120C and SINAMICS G120 with PM240-2 FSD … FSF
Power Module
-
✓
✓
✓
✓
✓
-
-
-
9
Efficiency-optimized operation of induction motors
Improved method "Efficiency optimization 2"
✓
✓
✓
✓
✓
✓
✓
✓
✓
10 New setting option for the "Technology application" p0500 = 5 during
quick commissioning
✓
✓
✓
✓
✓
✓
✓
✓
✓
11 Expansion of the available PROFIdrive telegrams in the SINAMICS
G120C to include telegram 350
-
✓
✓
✓
✓
✓
-
-
-
12 An SSI encoder can be parameterized as motor encoder
-
-
-
-
-
✓
-
✓
-
13 Expansion of the "Basic positioner" function to include the feedback signal
from traversing blocks to the higher-level control system
-
-
-
-
-
✓
-
✓
-