Technical specifications
8.4 Technical data
SINAMICS CONNECT
Operating Instructions, 10/2018, A5E45421408
87
Mechanical ambient conditions
Vibration resistance, tested in accordance with IEC 60068-2-6
Operation
Vibration load 1 g, 10 cycles per axis:
•
5 Hz to 8.4 Hz, deflection 3.5 mm
•
8.4 Hz to 200 Hz, acceleration 9.8 m/s
2
Storage/transport
•
5 Hz to 8.4 Hz: deflection 3.5 mm
•
8.4 Hz to 500 Hz: acceleration 9.8 m/s
2
Shock resistance, tested in accordance with IEC 60068-2-27
Operation
150 m/s
2
, 11 ms
Storage/transport
250 m/s
2
, 6 ms
8.4.3
Power demand of the components
Maximum power consumption of the auxiliary components
The information below applies to the horizontal mounting position of the device at an ambient
temperature of 50
°C and to the vertical mounting position of the device at an ambient
temperature
of 45 °C.
●
Maximum total power of all components: 6 W
NOTICE
Equipment damage due to overheat
The power supply cannot make unlimited power available. The auxiliary components
consume energy and produce heat. This may cause damage to the device and auxiliary
components.
•
Operate the device according to the relevant specifications.
•
Only operate the device in conjunction with effective temperature monitoring.
•
Immediately switch off the device if excessively high temperatures occur.
8.4.4
Direct current power supply (DC)
Technical specifications
Input voltage
9 V DC to 36 V DC
Power consumption
≤ 10 W