Description
08.2000
SLB - SIMOLINK Board
6SE7087-6NX84-0FJ0
Siemens AG
1-4
Operating Instructions
SIMOVERT MASTERDRIVES
The stored telegrams are archived in double-word connectors. A dedicated
connector is available for each of the eight stored telegrams. The output
telegrams are archived in BICO parameters.
The optional board can be supplied with the required operating voltage
internally from the converter/inverter, as well as externally. Priority is given to
the external voltage supply. Changeover is effected automatically on the
optional board.
NOTE
It is not permissible to change over from external voltage supply during bus
operation. During automatic changeover of the voltage supply, a reset signal is
generated on the optional board which results in the loss of some telegrams.
Telegram access
Voltage supply