SLB - SIMOLINK Board
08.2000
Description
Siemens AG 6SE7087-6NX84-0FJ0
SIMOVERT MASTERDRIVES
Operating Instructions
1-3
The optional board is provided with three LED displays for supplying
information on the current operating status.
System connector
Fixing screw
Fixing screw
LED (red)
LED (green)
LED (yellow)
X470 external 24 V voltage supply
SIMOLINK output (light gray)
SIMOLINK input (dark gray)
Fig. 1-2 View of the SLB optional board
The SLB optional board links the converters/inverters to SIMOLINK. It can be
used as the SIMOLINK dispatcher or as a SIMOLINK transceiver. The
functionality can be changed over by means of parameterization.
The optional board reads all telegrams on SIMOLINK and stores the selected
telegrams in a receive memory. There is also a separate memory area for the
telegrams which have to be changed or re-generated.
Mode of operation
Data traffic