Technical data of the D4x5-2
4.4 Power supply
SIMOTION D4x5-2
78
Manual, 02/2012
4.4
Power supply
External 24 V power supply
The control unit is supplied by an external 24 V power supply (e.g. SITOP).
The tolerance range for the input voltage of the SIMOTION D4x5-2 is between 20.4 and
28.8 VDC.
Table 4- 5
Power supply data
D425-2 DP
D435-2 DP
D425-2 DP/PN
D435-2 DP/PN
D445-2 DP/PN
D455-2 DP/PN
Power supply
•
Rated value
•
Permissible range
Safety extra-low voltage DVC A (PELV)
24 VDC
(20.4 ... 28.8 V)
Current consumption, typically
1)
0.7 A
1.0 A
1.9 A
Starting current, typically
1)
5 A
5 A
5 A
Power loss, typically
1)
17 W
24 W
46 W
1)
With no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interfaces
Table 4- 6
Input voltage specification
Input voltage
D4x5-2
Minimum input voltage
20.4 V
Nominal input voltage
24 V
Maximum input voltage
28.8 V
Table 4- 7
Specification of the input current - typical current consumption
Typical current consumption
1)
Device type
D425-2 DP
D435-2 DP
D425-2 DP/PN
D435-2 DP/PN
D445-2 DP/PN
D455-2 DP/PN
Minimum input voltage
0.8 A
1.2 A
2.24 A
Nominal input voltage
0.7 A
1.0 A
1.9 A
Maximum input voltage
0.6 A
0.8 A
1.58 A
1)
With no load on inputs/outputs and no 24 V supply via DRIVE-CLiQ or PROFIBUS interface
Summary of Contents for SIMOTION TB30
Page 10: ...Table of contents SIMOTION D4x5 2 10 Manual 02 2012 ...
Page 36: ...Description 1 9 CompactFlash card SIMOTION D4x5 2 36 Manual 02 2012 ...
Page 46: ...Operator control hardware 2 3 7 segment and LED displays SIMOTION D4x5 2 46 Manual 02 2012 ...
Page 72: ...Interfaces 3 10 USB interfaces SIMOTION D4x5 2 72 Manual 02 2012 ...
Page 134: ...Supplementary system components 6 11 DMC20 DRIVE CLiQ hub SIMOTION D4x5 2 134 Manual 02 2012 ...