10.8.3.2
SIMOTION Project Download online
The project data is loaded from a programming device with engineering system to the work
memory (RAM) and selected parameters (e.g. TCP/IP) to the SRAM or exchanged between
SRAM and work memory (RAM).
The explicit import of user data into the external CFast card is initiated by SIMOTION SCOUT
(Copy RAM to ROM).
Note
Identical names in SIMOTION SCOUT / Station Configurator are essential
It is essential for the download that the name of the station is identical in the engineering system
(SIMOTION SCOUT) and in the Station Configurator of the SIMOTION P320-4.
5HWDLQGDWD
.HUQHOGDWD
&XUUHQWGDWD
6WRUDJHPHGLXP
LQWHUQDO
66'
&)DVWFDUG
&)DVWFDUG
6WRUDJHPHGLXP
H[WHUQDO
2SHUDWLQJV\VWHP
6,027,21b3
)LUPZDUH
%DFNXSV
6,027,21b3
6WRUDJHPHGLD
8VHUGDWD
6,027,213
65$0
5$0
(QJLQHHULQJ6\VWHP
Figure 10-3 SIMOTION SCOUT download from the engineering system
SCOUT project download online process
1. Load the project data via SIMOTION SCOUT, menu Target system > Load > Load project
into target system..., into the working memory of the SIMOTION P320-4.
2. To transfer the data to the external storage medium, use the menu Target system > Copy
RAM to ROM in SIMOTION SCOUT.
The project data is transferred to the controller.
10.8.3.3
SIMOTION SCOUT - download of the project data (file structure)
The project data is saved by SIMOTION SCOUT in the form of the file structure in a file system
(e.g. a programming device with an engineering system).
The user copies this file structure to the external CFast card of the SIMOTION P320‑4.
This permits a series commissioning of SIMOTION programs.
Commissioning (software)
10.8 Data storage concept
SIMOTION P320-4 E / P320-4 S
Commissioning and Hardware Installation Manual, 11/2016