Application planning
4.4 Mounting positions and fastening
SIMOTION P320-3 and Panel Fronts
72
Manual, 02/2012
4.4
Mounting positions and fastening
Requirement
NOTICE
The device is approved for operation in closed rooms only.
Ensure that there is a minimum clearance to the other components or the walls of a
housing:
Below at least 100 mm
Above at least 50 mm
Mounting positions
Table 4- 1
Permissible mounting positions for the SIMOTION P320-3
Mounting position
Permitted temperatures / notes
Horizontal (preferred position)
in RAL: 0 to +55° C
Vertical
(power supply at the top)
0 to +45° C
Notes:
When mounted on a DIN rail, the device should be secured to
prevent shifting (e.g. with a DIN rail ground terminal).
See Section Mounting on DIN rails (Page 76)
Suspended
0 to +40° C
Note:
Mounting brackets are required if the device is suspended.
See Section Mounting with mounting brackets (Page 77)