Hardware description
3.2 SIMOTION P320-3 PC unit
SIMOTION P320-3 and Panel Fronts
Manual, 02/2012
39
3.2.4
Status displays
Status indicator
Status indicator
LED
Meaning
LED
Description
PWR
Power supply
GREEN
Indicates correct supply voltage of 3.3 V, 5 V and 12
V from the integrated power unit.
WD
Watchdog status
display
OFF
Not relevant.
OFF
SIMOTION P is operating without error.
RED: Slow flashing
(0.5 Hz)
No license exists for technology/optional objects
under license. Carry out the licensing to correct the
error.
Further information on the licensing can be found in
the SIMOTION P320-3 and Panel Fronts
Commissioning and Hardware Installation Manual.
RED: Fast flashing (2 Hz) A fault has occurred to which the user program
cannot respond.
The following actions may be required to rectify the
fault:
Power OFF/ON
New commissioning procedure
SF
Group errors
RED
An interrupt which can be acknowledged is present
(alarm, message, note).
(See Diagnostics Guide)
OFF
SIMOTION P Runtime is not running
YELLOW
SIMOTION P in STOP mode
RUN/STOP
RUN
STOP
GREEN
SIMOTION P in RUN mode
OFF
SIMOTION P is operating without error.
RED: Slow flashing
(0.5 Hz)
Underlicensing
RED: Fast flashing (2 Hz) No or faulty configuration.
SF PROFINET Status indicator for
PROFINET onboard
RED
Acknowledgeable event
Summary of Contents for SIMOTION P320-3
Page 14: ...Safety notes 1 2 Recycling and disposal SIMOTION P320 3 and Panel Fronts 14 Manual 02 2012 ...
Page 32: ...Description 2 4 SIMOTION panel fronts SIMOTION P320 3 and Panel Fronts 32 Manual 02 2012 ...
Page 100: ...Connecting 6 7 PROFINET strain relief SIMOTION P320 3 and Panel Fronts 100 Manual 02 2012 ...
Page 140: ...Standards and approvals A 3 Certificates SIMOTION P320 3 and Panel Fronts 140 Manual 02 2012 ...