Connections
The input block is connected with the output of the DCC_SCCAMERA DCC block using a unit-
global variable. The output signal is transferred to the camera measuring system via Ethernet.
Table 3-36
FB_Send_Preparation connections
Name
Type Data
type
"Camera" unit-global variables
Meaning
iDistanz
IN
DINT
camera_SC_Hoist_Height_PLC
Transfer external hoist position
from the PLC
aSendData
OUT ARRAY
[0..7] OF
BYTE
SendData
The data sent to the camera
measuring system
3.3.2.19
FB_ReadWrite_MV440
Symbol (FBD representation)
)%B5HDG:ULWHB09
%<7(
$55$<
LBDEXVHU
LBE6WDWXV
TBDEXVHU
TBE&WUO
TBE2.
TBZ(UURU
TBGL;
TBGL<
TBGL5RW
TBGL'LVW
TBGL;BY
$55$<
%<7(
%22/
:25'
',17
',17
',17
',17
',17
TBGL<BY
TBGL5RWBY
TBGL'LVWBY
TB&RXQWHU
',17
',17
',17
',17
,17
',17
LBGL7LPH2XW
LBGL([W'LVW
Figure 3-33
FB_ReadWrite_MV440
Task
The block prepares the send and receive addresses for the camera measuring system.
This block is used if PROFINET has been selected as the camera communication system.
Overview of the software
3.3 Sway control function blocks
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
81