P115 Configuration of prelimit switches
Deceleration of the trolley and the hoist before the minimum or maximum position to prelimit
switch velocity. The dynamic prelimit switches (P24, P27, P64, P68) are enabled and disabled.
Meaning:
0
Dynamic prelimit switches deactivated, bits for prelimit switches active
1
Dynamic prelimit switches activated.
Default: #0
Access code: 1
Display: Always
P119 Lowering point in SAM travel from WS to LS
You will find more information in Chapter Influencing the lowering point in SAM travel from WS
0
Fixed offset in the trolley direction (P26 + 2 * P106)
1
Internally calculated lowering point
Default: #0
Access code: 1
Display: Always
11.6
Camera measuring system/reflector
P120 Assignment of the camera measurement direction
Assignment of trolley travel direction to the measurement direction (x, y) of the camera.
Selection:
1
Motion up or down corresponds to the trolley travel.
2
Motion to the left corresponds to the forward direction.
3
Motion up corresponds to the forward direction.
Default: #...
Access code: 1
Display: Only for STS (P102, selection 1 = ON)
Note
The directions specified refer to the camera image.
(See Chapter Commissioning steps in the commissioning menu (Page 331); Section "Set the
alignment of the camera (commissioning step 1)")
Parameters
11.6 Camera measuring system/reflector
SC integrated STS, GSU
412
Operating Instructions, 07/2019, A5E48271265B AA