Commissioning (software)
4.6 Creating and testing an axis
SIMOTION D410
Commissioning Manual, 02/2012
103
4.
Read the notes and confirm these with "Accept".
5.
Activate the "Enables" checkbox to enable the drive.
All enables are now set with the exception of ON/OFF1.
6.
Enter your setpoint in the input field and shift the scaling to 0% as safety setting.
Figure 4-18 Entering the setpoint
7.
Click the "Drive On" button. The "Enable is set" LED lights up in green color. The drive
starts moving as you move the slider towards the right side. The current motor speed is
displayed in "Actual".
8.
Click "Drive Off" to stop the drive after you completed the test.
9.
Deactivate the enable and click the "Give up control priority" button to deactivate control
by the PG/PC.
4.6
Creating and testing an axis
4.6.1
Overview of SIMOTION Engineering
Performing engineering with SIMOTION SCOUT
The SIMOTION SCOUT Engineering Software is used to add axes to your project.
1.
Start a session of the Axis Wizard in order to configure the axes and interconnect these
with the SINAMICS Integrated drive.
2.
Provided you have completed the configuration at the drive end, we strongly recommend
for faster working that the SINAMICS Integrated is deactivated via "Target system" >
"Select target device".