Nominal size
Cable gland for Ex e II
TypeHSK-M
Cable gland for Ex e / Ex d IIC
Type ADE 1F, ADE 4F R... / B...
Union nut
Connection thread
Union nut / connection
thread
Union nut / connection
thread
M20 x 1.5
5
7
20
23
M25 x 1.5
7
10
30
29
M32 x 1.5
7
10
55
33
M40 x 1.5
7
10
75
41
M50 x 1.5
7
10
100
50
M63 x 1.5
7
10
135
75
M75 x 1.5
-
-
175
100
6.2.12
Connecting aluminum conductors
If you are using aluminum conductors, comply in addition with the following:
● Use only cable lugs that are suitable for connecting aluminum conductors.
● Immediately before inserting the aluminum conductor, remove the oxide layer from the
contact areas on the conductor and/or the mating piece, by brushing or filing.
● Then grease the contact areas immediately using neutral vaseline in order to avoid re-
oxidation.
NOTICE
Aluminum flow due to contact pressure
Aluminum flows following installation due to the contact pressure. The connection with the
clamping nuts can loosen as a result. The contact resistance would increase and the
current-carrying impeded; as a consequence the terminal box and the surrounding
components could burn. This could result in material damage to the machine or even in
total failure, which could in turn lead to indirect material damage to the system.
Retighten the clamping nuts after approximately 24 hours and then again after
approximately four weeks. Make sure that the terminals are de-energized before you
tighten the nuts.
6.2.13
O-ring seal
If O-ring seals are present, you should check that they are in perfect condition and that the O-
ring seals are properly seated in the grooves between the components. Replace any damaged
O-ring seals.
O-ring seals can be present on the following components, for instance:
● Tapers
● Cable glands
● Bearing seals
Electrical connection
6.2 Connecting
SIMOTICS XP 1MD4/1MD5
58
Operating Instructions 05/2015
Summary of Contents for SIMOTICS XP 1MD4
Page 2: ...13 07 2015 11 26 V8 00 ...
Page 10: ...Table of contents SIMOTICS XP 1MD4 1MD5 10 Operating Instructions 05 2015 ...
Page 12: ...Introduction SIMOTICS XP 1MD4 1MD5 12 Operating Instructions 05 2015 ...
Page 20: ...Safety notes 2 11 Ventilation SIMOTICS XP 1MD4 1MD5 20 Operating Instructions 05 2015 ...
Page 26: ...Description SIMOTICS XP 1MD4 1MD5 26 Operating Instructions 05 2015 ...
Page 50: ...Assembling 5 3 Installing the machine SIMOTICS XP 1MD4 1MD5 50 Operating Instructions 05 2015 ...
Page 74: ...Operation 8 7 Faults SIMOTICS XP 1MD4 1MD5 74 Operating Instructions 05 2015 ...
Page 90: ...Maintenance 9 2 Repair SIMOTICS XP 1MD4 1MD5 90 Operating Instructions 05 2015 ...
Page 110: ...Disposal 11 4 Disposal of components SIMOTICS XP 1MD4 1MD5 110 Operating Instructions 05 2015 ...
Page 126: ...Index SIMOTICS XP 1MD4 1MD5 126 Operating Instructions 05 2015 ...
Page 127: ...AE EC Declaration of Conformity U161 AD EC Declaration of Conformity U163 AA R No 20000h U165 ...