Operation
8.2 Switching on the machine
1MB155 / 1MB555
Operating Instructions, 03/2018, A5E41926185A
99
8.2
Switching on the machine
1.
If at all possible, run the machine without load and check that it is running smoothly.
2.
If it runs perfectly, connect a load.
NOTICE
Thermal overload of motors connected directly to the line supply
In addition to the load torque, the ramp-up (accelerating) time is essentially influenced
by the moment of inertia to be accelerated. While ramping up when connected to the
line supply, the inrush (starting) current is a multiple of the rated current. This can result
in thermal overload. This can damage the motor.
As a consequence, when ramping up, observe the following:
•
Monitor the ramp-up time and number of consecutive starts.
•
Comply with the limit values and/or ramp-up conditions specified in the catalog or the
order documentation.
3.
If this is possible using the available measuring equipment, check the bearing and stator
winding temperatures.
8.3
Switching off the external fan
Do not immediately switch off the separately-driven (external) fan after switching off the
machine. First wait for the machine to cool down. This will prevent the accumulation of
residual heat.
8.4
Switching on again after an emergency switching-off
●
Check the machine before recommissioning the driven machine after an Emergency Off.
●
Eliminate all the causes that have led to the emergency off
8.5
Stoppages
The stoppage is a shutdown for a period of time, during which the machine is stopped but
remains at the location of use.
Under normal ambient conditions, e. g. the stopped machine is not exposed to any vibration,
no increased level of corrosion, etc. in general, the following measures are necessary during
stoppages.
Summary of Contents for SIMOTICS XP 1MB155
Page 1: ......
Page 2: ......
Page 10: ...Table of contents 1MB155 1MB555 8 Operating Instructions 03 2018 A5E41926185A ...
Page 94: ...Start up 7 2 Switching on 1MB155 1MB555 92 Operating Instructions 03 2018 A5E41926185A ...
Page 108: ...Operation 8 6 faults 1MB155 1MB555 106 Operating Instructions 03 2018 A5E41926185A ...
Page 144: ...Service and Support 1MB155 1MB555 142 Operating Instructions 03 2018 A5E41926185A ...
Page 152: ......