![Siemens SIMOTICS-T 1FW6 Series Operating Instructions Manual Download Page 30](http://html.mh-extra.com/html/siemens/simotics-t-1fw6-series/simotics-t-1fw6-series_operating-instructions-manual_379084030.webp)
Description
2.2 Technical features and ambient conditions
Naturally cooled 1FW6 built-in torque motors
30
Operating Instructions, 07/2017, 6SN1197-0AF02-0BP2
2.2.4
Defining the direction of rotation
Direction of rotation
If the built-in torque motor is connected with a phase sequence U-V-W, and is fed from a
three-phase system with a clockwise phase sequence, then the rotor rotates clockwise. You
can identify the direction of rotation by viewing the DE of the built-in torque motor. The cable
outlet of the built-in torque motor is on the opposite side – the NDE.
Figure 2-2
Line of sight for determining the direction of rotation