![Siemens SIMOTICS T-1FW4407-1KM81-1BC0-Z Operating Instructions Manual Download Page 25](http://html.mh-extra.com/html/siemens/simotics-t-1fw4407-1km81-1bc0-z/simotics-t-1fw4407-1km81-1bc0-z_operating-instructions-manual_379070025.webp)
Preparations for use
4
Good planning and preparation of machine applications are essential in terms of keeping
installation simple and avoiding errors, ensuring safe operation, and allowing access to the
machine for servicing and corrective maintenance.
This chapter outlines what you need to consider when configuring your plant in relation to this
machine and the preparations you need to make before the machine is delivered.
4.1
Safety-related aspects to consider when configuring the plant
A number of residual risks are associated with the machine. These are described in the chapter
titled "Safety information" (Page 13) and in related sections.
Take appropriate safety precautions (covers, barriers, markings, etc.) to ensure the machine
is operated safely within your plant.
4.2
Observing the operating mode
Observe the machine's operating mode. Use a suitable control system to prevent overspeeds,
thus protecting the machine from damage.
4.3
Cooling water quality
The values specified for the cooling water correspond to the requirements for a closed cooling
circuit. Not all of the specified concentrations will occur in the cooling water at the same time.
You can use a filter to ensure disturbance-free operation. The filter mesh size should not be
less than 100 μm.
Observe any order-specific agreements regarding the cooling water specification. These might
deviate from the cooling water specification given above.
The cooling system is maintenance-free provided cooling water of the specified quality is used.
Cooling water specification
Table 4-1
Cooling water specification
Constituent
Value
pH value
6.0 … 9.0
Total hardness
< 170 ppm
Conductivity
< 500 μS/cm
Chloride ions
< 40 ppm