![Siemens SIMOTICS S-1FK2 Operating Instructions Manual Download Page 202](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045202.webp)
8.2.2
Converter ambient conditions
Property
Version
Ambient conditions for transport in the transport packaging
Climatic ambient conditions ‑40 °C … +70 °C, according to Class 2K4 to EN 60721‑3‑2
maximum humidity 95 % at 40 °C
Mechanical ambient condi‐
tions
Shock and vibration permissible according to 2M3 to EN 60721‑3‑2
Protection against chemical
substances
Protected according to Class 2C2 to EN 60721‑3‑2
Biological environmental
conditions
Suitable according to Class 2B2 to EN 60721‑3‑2
Ambient conditions for long-term storage in the product packaging
Climatic ambient conditions
1)
‑25 °C … +55 °C, according to Class 1K4 to EN 60721‑3‑1
Protection against chemical
substances
Protected according to Class 1C2 to EN 60721‑3‑1
Biological environmental
conditions
Suitable according to Class 1B2 to EN 60721‑3‑1
Ambient conditions in operation
Installation altitude
● Up to 1000 m above sea level without restrictions
● Up to 4000 m, restrictions, see the following table
Climatic ambient conditions ● Temperature range: 0 °C … +50 °C
● Relative humidity: 5 … 95%, condensation not permitted
● Oil mist, salt mist, ice formation, condensation, dripping water, spraying water, splashing
water and water jets are not permitted
Increased ruggedness regarding temperature range and relative humidity; therefore better
than 3K3 according to EN 60721-3-3
Mechanical ambient condi‐
tions
● Vibration levels permissible according to Class 3M2 to EN 60721-3-3
Vibration test in operation according to IEC 60068-2-6 Test Fc (sinusoidal)
– 10 Hz … 13 Hz: 0.075 mm deflection amplitude
– 13 Hz … 150 Hz: 1 g acceleration amplitude
– 10 frequency cycles per axis
● Shock permissible according to Class 3M2 to EN 60721-3-3
Shock test in operation according to IEC 60068-2-27 Test Ea (half sinusoidal)
– 5 g peak acceleration
– 30 ms duration
– 3 shocks in all three axes in both directions
Protection against chemical
substances
Protected according to 3C2 to EN 60721‑3‑3
Biological environmental
conditions
Suitable according to 3B2 to EN 60721‑3‑3
Pollution
Suitable for environments with degree of pollution 2 according to EN 61800-5-1
Technical specifications
8.2 Technical specifications of the converter
SINAMICS S210 servo drive system
200
Operating Instructions, 12/2017, A5E41702836B AA
Summary of Contents for SIMOTICS S-1FK2
Page 2: ......
Page 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Page 767: ......