![Siemens SIMOTICS S-1FK2 Operating Instructions Manual Download Page 185](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045185.webp)
Select the measuring points according to ISO 10816-1 section 3.2. The vibration values must
not exceed the specified limits at any measuring point.
Measuring points for vibration values
1 End shield DE radial
2 End shield DE radial
3 End shield DE axial
4 End shield NDE radial
5 End shield NDE axial
6 End shield NDE radial
8.1.8
Shaft extension
The motors are supplied with cylindrical shaft extensions. The shaft extension usually has a
centering thread according to DIN 332, form DR.
Optionally, a shaft extension can also be supplied with a keyway and feather key.
With the IP65 degree of protection, the useable shaft extension is reduced by the radial shaft
sealing ring.
Shaft
height
Shaft dimensions
Diameter x length in mm
Shaft dimensions with
IP65
Diameter x length
in mm
Feather key
Width x height x
length in mm
Centering thread
DIN 332-DR
20
8 x 25
8 x 18
2 x 2 x 10
M3
30
14 x 30
14 x 21.5
5 x 5 x 16
M5
optional 11 X 23
1)
-
-
M4
40
19 x 40
19 x 32
6 x 6 x 22
M6
1)
The optional 11 mm x 23 mm shaft extension is only available without a keyway and without
a shaft sealing ring (IP65).
Technical specifications
8.1 Technical data and properties of the motor
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
183