Commissioning
6.3 "Premium Performance" bearing version
1PH808/1PH810 main motors
Operating Instructions, 04/2017, 610.48004.40f
113
6.3
"Premium Performance" bearing version
Note
Parameters must be adapted when commissioning
Motors with the "Premium Performance" bearing version are presently not plug & play
components. After automatically commissioning the motors with DRIVE-CLiQ, the
commissioning engineer must adapt the appropriate parameters. Example: Motors with V
and W winding versions (10th position of the Article No.) require a 8 kHz pulse frequency.
Presently, this value is not automatically set. Further, for these motors, the current controller
must be adapted. These parameters are currently not saved in the DRIVE-CLiQ interface
data. The commissioning engineer must manually adapt these parameters. These motors
may only be operated with a fast current controller (p1810.11 = yes) when connected to the
SINAMICS S120 drive system.
In order that you can proceed precisely when commissioning the motors, please request the
commissioning regulations from your Siemens Service Center. The contact data is provided
in the introduction under Technical support.