Connection
5.2 Electrical connection
1PH808/1PH810 main motors
Operating Instructions, 04/2017, 610.48004.40f
101
5.2.12
Connecting the external fan on 1PH810
The fan connection is located in the fan terminal box.
If you order the motor with a power connector, the external fan is connected with a size 1
power connector (see section "Connecting the external fan on 1PH808").
Table 5- 5
Connection specifications for external fans with 1PH810
Air flow direc-
tion
Max. current consumption at
400 V / 50 Hz (±10 %)
[A]
400 V / 60 Hz (±10 %)
[A]
480 V / 60 Hz (±10 %)
[A]
NDE --> DE
0.12
0.09
0.12
DE --> NDE
0.13
0.09
0.13
Note the following information regarding connections:
●
Only use cables that comply with the relevant installation regulations regarding voltage,
current, insulation material, and load-carrying capacity.
●
Before connecting the device, make sure that the line voltage matches the device
voltage.
●
Check whether the data on the fan rating plate matches the connection data.
●
Open the terminal box and route the cables (not supplied) into the terminal box.
●
Connection cables must not be subject to excessive tensile stress.
●
Connect the protective conductor (PE).
●
Connect the other cables to the relevant terminals (refer to the connection diagrams).
Summary of Contents for SIMOTICS M-1PH8
Page 1: ......
Page 2: ......
Page 8: ...Introduction 1PH808 1PH810 main motors 8 Operating Instructions 04 2017 610 48004 40f ...
Page 12: ...Table of contents 1PH808 1PH810 main motors 12 Operating Instructions 04 2017 610 48004 40f ...
Page 148: ...Spare parts 1PH808 1PH810 main motors 148 Operating Instructions 04 2017 610 48004 40f ...
Page 185: ......
Page 186: ......